Danfoss RET MD 사용자 설치 설명서
{카테고리_이름} Danfoss RET MD에 대한 사용자 설치 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Danfoss RET MD 2 페이지. Electronic intelligent room thermostat
Electronic Intelligent Room Thermostat
thermostat power on
-
Turn setting dial to required temperature which is displayed momentarily on the LCD display. The LCD reverts to
displaying actual room temperature within a few seconds.
-
If Time Control is activated the green LED is lit.
-
If the red LED is lit constantly, the heating is switched on.
-
If the red LED is flashing, the Delay Start function is in operation.
-
If the Save button is pressed while the heating is on, the Delay Start function will start. This can save energy by
switching the heating off once the room is up to temperature for the duration of the delay period (refer to Delay Chart
overleaf). Pressing the Save button a second time will return the thermostat to normal operation and the heating will
start.
-
If the green LED is on, but the red LED is off, the room temperature has been reached and the thermostat is satis-
fied. If more heat is required turn the setting dial to increase the set temperature.
User & Installation Guide
RESET button
(behind dial)
Green LED -
RET MD
Temperature display LCD
Setting Dial
Red LED -
heating is operational
Save Button