6
Frost Protection Temperature and Reset
• You can switch the thermostat OFF (Standby) by alternately pressing
stat is set to a Frost Protection temperature setting and will switch On only if the measured temperature falls
below this temperature (5 °C by default).
• The frost protect icon and current temperature will be displayed.
• At this point, if the
7
Set Control Parameters
• Press M button for 6 seconds to enter the parameter setting mode. Press M for parameter selection and set
the parameter range via < or >. Complete all adjustments.
• To exit press upper part of setting ring or wait 20 secs for automatic exit.
The digits indicate the set value as follows:
No.
Parameter settings
P02
Heat control mode
P04
Temperature limit high
P05
Temperature limit low
P06
Frost protect temperature
P07
Away mode temperature
P10
RF Pairing (RET2001RF only)
8
Error Messages
E1
Sensor failure
EE
EEPROM failure
Lo
Measured temperature below 0 °C
Hi
Measured temperature above 50 °C
E3
RF Pairing failed
E4
RF Signal lost
Danfoss Heating
RET2001 Digital Room Thermostats
button is pressed for 10 seconds Continuously then the thermostat will be reset.
01: On/off load compensation
02: On/off standard
Between low (P05) and 35 °C
Between 5 °C and high (P04)
Between 5 °C and 15 °C
Between low (P05) and high (P04)
00: RF pairing mode off
01: RF pairing mode on
. In OFF (Standby) mode, the thermo-
Settings range
VUSUD102
Default
01
35 °C
5 °C
5 °C
18 °C
00