3T-Components 3T-MOTORS 3T45-10B 설치 및 운영 지침 매뉴얼 - 페이지 16

{카테고리_이름} 3T-Components 3T-MOTORS 3T45-10B에 대한 설치 및 운영 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. 3T-Components 3T-MOTORS 3T45-10B 20 페이지. Shutter / awning motors

3T-Components 3T-MOTORS 3T45-10B 설치 및 운영 지침 매뉴얼

TROUBLESHOOTING

WHAT TO DO WHEN ...

... the motor does not run?
Mains voltage is missing.
Check correct connection of the control (switch or timer).
... the motor is running in the wrong direction?
Swap the two wires for the direction of rotation (brown + black).
... the motor does not switch off at the set point?
Check fit of limit switch adapter (must be flush with motor head and shutter shaft).
Roller capsule is not fixed or roller shutter shaft is too short.
... the motor does not switch off at all?
Limit switches are too far apart: See setting the end points with set button or ESK setting cable (roller shutter motor: page 11 / awning motor: page 15).
... the motor stops running after continuous operation?
The thermal protection switch of the motor has tripped. After a cooling phase (min. 10 min.), the motor is ready for operation again.
... the motor turns in only one direction?
Check correct connection of the control (switch or timer).
Check limit switch: See setting the end points with set button or ESK setting cable (roller shutter motor: page 11 / awning motor: page 15).
... the motor does not operate at the specified speed?
Check roller shutter weight; if necessary, correct inclined installation of roller shutter shaft or Eliminate mechanical friction in the roller shutter box or rail guide.
3T-MOTORS Tubular motors | Troubleshooting
16