10.1 Spring replacement
1
Remove protective cap A.
3
Remove adjusting nut B.
2
Turn outer adjusting
nut B anti-clockwise
with SW 14 socket
spanner until it is com-
pletely unscrewed.
A
4
1. Remove
from the spring dome.
2. Insert a new spring.
3. Screw adjusting nut B
in with SW 14 socket
spanner until the pre-
B
tension required in
the spring dome is
reached.
(-)
spring
C
C
16 ... 20