Disassembling and Assembling, APP 1.5-3.5
Service guide |
4 | 180R9091 | DKCFN.PI.013.EF5.02 | 521B0741
7. Remove the cylinder barrel.
9. Gently lever the valve plate assembly free
with the aid of a screwdriver.
11. Gently press, by hand, the valve onto the
cylinder barrel.
8. Remove the port plate.
Mount backup
ring first
Then mount
O-ring
10. Replace the O-rings and the back-up rings
on the valve plate. Mount the new back-
up rings on the new valve plate first and
then mount the new O-rings.
Wet the O-rings and back-up rings with
clean (filtered) soap water.
12. Gently push flushing valve out using the
Allen key.
© Danfoss | DCS (im) | 2017.08