{카테고리_이름} Danfoss H1T Series에 대한 전기 설치을 온라인으로 검색하거나 PDF를 다운로드하세요. Danfoss H1T Series 12 페이지. 3-position (fnr) electric control

Electrical Installation
Product overview

Theory of operation

Hydraulic schematics

Electrical specifications

6
H1 Pump 3-Position (FNR) Electric Control
The 3-position (FNR) Electric Control uses an electric input signal to switch the pump to a full stroke
position.

Pump displacement versus electrical signal

100 %
0
Voltage Vdc
100 %

Hydrostatic drive line power

W
Warning
Unintended vehicle or machine movement hazard. The loss of hydrostatic drive line power, in any mode
of operation (forward, neutral, or reverse) may cause the system to lose hydrostatic braking capacity. You
must provide a braking system, redundant to the hydrostatic transmission, sufficient to stop and hold the
vehicle or machine in the event of hydrostatic drive power loss.
M14
C2
F00B
F00A
H1 pump 3-position (FNR) electrical specifications
Voltage
Minimum supply voltage
Maximum supply votage
Rated power
Coil resistance at 20º C [70º F]
11025001 • Rev BA • September 2015
C1
T
P
12V
9.5 Vdc
14.6 Vdc
17 W
8.4 Ω
24V
19 Vdc
27 Vdc
17 W