7. Mechanical installation

The Plug&Spray
units can be floor mounted. It is also possible to
TM
mount the unit on supports on a wall.
The optional electric connecting box can be factory-installed, mounted
on a suitable wall or on supports at eye level on the pump unit.
Dimensions, mm (in)
Mounting plate
Free-standing arrangement:
For free-standing arrangement, the optional electric connecting box
or, as required, the control unit is mounted on supports at the pump
unit. The supports are dismantled during transport.
The upper support part is inserted into the bottom part during instal-
lation and joined together with the supplied screws.
NB: The mounting plate must be fixed to the floor with 4 bolts to secure
the system against tipping.
Compact design:
The Plug&Spray
the floor with 4 bolts. If required, the unit can also be placed on angle
supports mounted in required height. The optional connecting box is
mounted on the pump unit from factory.
Wall mounting:
In units for wall mounting, the optional electric connecting box or, as
required, the control unit is connected to the pump unit by a 2-metres
cable from factory. Usually the pump unit is placed on the floor and the
connecting box wall mounted.
521B0881 DKCFN.PI.020.F1.02
unit is placed on a suitable flat area and fixed to
TM