Danfoss PAHT 12.5 분해 및 조립 - 페이지 11

{카테고리_이름} Danfoss PAHT 12.5에 대한 분해 및 조립을 온라인으로 검색하거나 PDF를 다운로드하세요. Danfoss PAHT 12.5 20 페이지.

Danfoss PAHT 12.5 분해 및 조립
Instruction
Disassembling and assembling PAH 10-12.5, PAHT 10-12.5 and PAHT G 10-12.5
5.
Mount the valve plate with seals on the
cylinder barrel.
7.
Check that the gap between the cylinder
barrel and the valve plate is 1.5-2.5 mm.
9.
Mount the spring in the centre hole.
180R9095 / 521B0986 / DKCFN.PI.010.NA3.02 / 09.2013
6.
Press the valve plate into the cylinder barrel
using a piece of plastic.
8.
Mount the cylinder barrel in the flange.
10.
Mount the spring guide.