Tall Pedestal Kit for FK11/FB11 and FK12/FB12
Installation Guide
4.
Verify that the top clearance for air exhaust is at least 225 mm (9 in).
5.
Verify that the air intake at the bottom front of the frequency converter is unobstructed.
6.
Around the top of the pedestal, secure the cabinet using 6 M10x22 screws.
Refer to
Illustration
7.
Loosely tighten each fastener until all are installed.
Torque each fastener to 19 Nm (169 in-lb).
1
2
3
4
Illustration 3: Pedestal-to-Cabinet Back Mounting Points
1
Cabinet
2
Pedestal
3
Bolt at rear of pedestal
1
2
3
Illustration 4: Pedestal-to-Cabinet Front Mounting Points
Danfoss A/S © 2022.03
4.
1
5
6
4
M10 nylon insert lock nut
5
Locking bracket
6
Slotted hole in cabinet
AN361529835714en-000101 / 136R0257 | 5
Installation