3.
With the rubber seal in place, carefully slide the inner sleeve of each duct into the outer sleeve.
1
2
3
Illustration 7: Assembly of Telescopic Ducts
1
Inner sleeve of duct
2
Ribbed EPDM rubber seal
2.6 Installing the Top Duct Over the Top Vent
To attach the top duct over the top vent of the frequency converter, use the following steps. See
Procedure
1.
Remove 2 M5x14 screws (T25) at the back of the top vent, and retain the screws.
2.
Remove 3 M5x12 screws (T25) at the front of the top vent, and retain the screws.
3.
Position the top duct over the vent in the top of the frequency converter.
4.
Line up the holes in the lower flange with the screw holes in the frequency converter.
5.
Secure the lower flange to the frequency converter with 5 screws (T25) previously removed.
Torque fasteners to 2.3 Nm (20 in-lb).
8 | Danfoss A/S © 2022.12
3
Outer sleeve of duct
Illustration
AN361429548582en-000201 / 136R0255
Installation
8.