A. Remove parts package, control box, and thermostat from the 3104998.XXX Kit Carton.
B. Freeze Control Installation 579, 590, 591, & 595 Series Brisk Air Models (See Fig. 7.)
1. Snap freeze control into place on return bend located at left side of evaporator coil as follows:
a. Locate "D" shaped notch in flange of evaporator coil.
b. Place the horseshoe end of the freeze control through this notch and snap onto the coil return bend. When positioned
correctly, control wires will be 90
c. Remove installation notice hang tag from freeze control.
C. Freeze Control installation on 600 Series Penguin Models (See Fig. 8.)
1. Snap freeze control into place on return bend located at right side of evaporator coil as follows:
a. Locate "D" shaped notch in flange of evaporator coil.
b. Place the horseshoe end of the freeze control through this notch and snap onto the coil return bend. When positioned
correctly, control wires will be 90
c. Remove installation notice hang tag from freeze control.
8. INSTALLATION OF COLD CONTROL
0
to direction of coil fin surface.
Brisk Air Model Series
FIG. 7
579, 590, 591, & 595
Coil
Return
Bend
Freeze Control
With Wires To Left Side
0
to direction of coil fin surface.
Penguin Model Series 600
FIG. 8
Remove
Hang Tag
Freeze Control
With Wires To Right Side
INSTALLATION INSTRUCTIONS DUCTED BI-METAL
Remove
Hang Tag
Coil
Return
Bend