Setting Operation Type of MIDI Clock (MD-CK): ON/OFF switch 4

MD-CK
ENTER
 Turn the PARAMETER encoder to select the desired operation type.
Parameter 1: THRU, INTERNAL [INT], OFF (default = THRU)
NOTE
THRU: The MIDI clock received at the MIDI IN terminal is sent intact to the device connected to the MIDI OUT/THRU terminal. The MIDI CLOCK dot in the Display-1 will not flash and the
Display-2 will not show "BPM."
INTERNAL [INT]: BPM set in the ARC-4 is fed to the device connected to the MIDI OUT/THRU terminal as a MIDI clock. The MIDI CLOCK dot in the Display-1 flashes in sync with BPM,
the Display-2 shows "BPM."
OFF: When a MIDI clock is received at the MIDI IN terminal, it is not sent to the device connected to the MIDI OUT/THRU terminal.
Setting whether to Output TAP Information or Not (TP-DT): ON/OFF switch 5
TP-DT
ENTER
 Turn the PARAMETER encoder to select ON or OFF.
Parameter 1: ON, OFF (default = OFF)
NOTE
This sets whether to send the TAP information when the footswitch assinged to the TAP tempo input function is pressed.
Turn on this function when TAP tempo information is sent to a device not supprting MIDI clock.
SETUP: PS6/L6 Switch
Basic settings of the ARC-4 are done in these configuration modes.
Setting Operation Mode when Two ARC-4 Units are Connected with Dedicated Link Cable (LK-MD): ON/OFF switch 1
LK-MD
ENTER
 Turn the PARAMETER encoder to select the desired operation mode.
• In NORMAL mode, the preset numbers on the two unites always synchronize together. But preset contents are configured separately.
• In MASTER/SLAVE mode, the settings and presets on the MASTER unit are prioritized and executed. The SLAVE unit serves as a remote controller.
N.B. If set to MASTER/SLAVE mode, the device you want to turn on/off by the effect loop or the device you want to control via MIDI must be connect to the
MASTER side.
Parameter 1: NORMAL, MASTER, SLAVE (default = NORMAL)
NOTE
For more about the link cable dedicated for the ARC-4, please contact your local dealer or Free The Tone directly.
Setting Initial Operation Mode when ARC-4 is Powered On (OP-MD): ON/OFF switch 2
OP-MD
ENTER
 Turn the PARAMETER encoder to select the desired operation mode.
Parameter 1: BANK, DIRECT, LIST1 to LIST9 (default = BANK)
20
THRU
MD-CK
PARAMETER
ENTER
OFF
TP-DT
PARAMETER
ENTER
NORMAL
LK-MD
PARAMETER
ENTER
BANK
OP-MD
PARAMETER
ENTER
NOTE
BANK: Factory shipping status. The ARC-4 starts in Preset mode. Banks are organized in the order of bank numbers and recalled by using these numbers.
DIRECT: The ARC-4 starts in Direct mode.
LIST1–9: The ARC-4 starts in Preset mode. Banks are maintained and recalled by the order set by the setlists.
Setting Function to be Assigned to EFS-3 Connected to OPTION-1 (EFS-3) Terminal and PS/L Switch on ARC-4 (FS-AS): ON/OFF switch 3
FS-AS
E1
ENTER
PARAMETER
ENTER
 Turn the PARAMETER encoder to select the desired footswitch.
 Turn the PARAMETER encoder to select the desired function.
N.B. The operation type is selected from LATCH and HOLD.
Parameter 1: E1 to E4, PS1 to PS7
Parameter 2: LOOP1 to 8, CTL1 to 4, INVERT, BOOST, MUTE- A, MUTE- B, CSW1 to 8
Parameter 3: LATCH, HOLD
N.B. Default assignments E1: PS8, E2: PS9, E3: PS10, E4: EXP PEDAL [PEDL], and PS1 to PS7 cannot be assigned to another switch.
NOTE
LATCH: Pressing the switch once turns on its function and pressing it again turns it off.
HOLD: The function of the switch is activated as long as it is held pressed.
N.B. When PS1–10 is selected, there is no option other than LATCH. It is not possible change the parameter.
Setting Operation Type of Control Signal to be Sent (RL-CT): ON/OFF switch 4
RL-CT
CTL1
ENTER
PARAMETER
 Turn the PARAMETER encoder to select the desired control terminal.
 Turn the PARAMETER encoder to select the desired operation type.
Parameter 1: CTL1 to CTL4
Parameter 2: LATCH, MOMENTARY1 [MOM1], MOMENTARY2 [MOM2] (default = LATCH)
MOMENTARY1 (MOM1):
The contact closes for 100 ms only when CONTROL is turned on to execute a momentary operation. Use this mode to control an
amplifier channel that supports momentary switching.
MOMENTARY2 (MOM2):
The contact closes for 100 ms when CONTROL is turned on and off to execute a momentary operation. Use this mode to control
a device that controls functions such as effect on/off via momentary switching.
Setting Operation Type of MUTE Switch (MT-MD): ON/OFF switch 5
MT-MD
ENTER
 Turn the PARAMETER encoder to select the desired operation type.
• AUTO: The Mute function is automatically cleared when the PS/L switch is pressed in the mute status and a preset is recalled.
• MANUAL: The Mute function is not cleared when the PS/L switch is pressed in the mute status and a preset is recalled. The Mute function is cleared when the
MUTE switch is pressed again.
• OFF: The MUTE switch does not operate.
Parameter 1: AUTO, MANUAL, OFF (default = AUTO)
PS8
LATCH
PARAMETER
ENTER
ENTER
 LATCH
CTL1
ENTER
PARAMETER
ENTER
MT-MD
AUTO
ENTER
PARAMETER
E1