Duomo HCF100 운영 - 페이지 3

{카테고리_이름} Duomo HCF100에 대한 운영을 온라인으로 검색하거나 PDF를 다운로드하세요. Duomo HCF100 8 페이지. Duct refrigeration gas sensor

Overall Dimensions HCF100 Duct (mm)
100mm
8
7
6
5
4
Connections and LED indicator

CONNECTING TERMINAL

1. Positive Supply Voltage
2. 0V
3. Return Sensor Voltage
4. Relay common
5. Relay output
POWER ON LED
This LED illuminates Green when power is ON and the sensor has a power supply from the controller.
Flashing red indicates gas is being detected.
Constant red indicates alarm state.
Constant Amber indicates fault condition.

DIAGNOSTIC PORT

This can be connected to a A hand-held datalogger that can printout information about the sensor (serial number, powering
up information, sensor condition, alarm activations, expected lifespan, auto adjusts made and the preset calibration state.
t: 01905 797989
e: sales@duomo.co.uk | w: www.duomo.co.uk
57mm
5
4
3
2
8
7
6
5
4
245mm
72mm
Connecting Terminal
1
Power ON LED
Diagnostic port
3
Not to scale