3.5 Switch the ignition key to ON and
start cranking the engine until it
starts. Immediately after that press
ENTER
key and the results will show
as follows:
Cranking Test
MinVolts: 10.26V
VoltDrop:
Normal
Result:
OK
3.6 If the voltage drop is too great during
the cranking, the tested results will
display as follows (Figure 45) and will
prompt you to check the starter
system.
Min Volts: 7.96V
VoltDrop:
HIGH
Chk Starter Sys
Battery has aged
If voltage reading less than 8.5V
3.7 During cranking when it detects that
there is no drop in voltage, it will
display the following screen:
Cranking Test
Not detected . . .
Check connection
and test again
3.8 To exit the program, pressing the
key at any moment will exit and return
back to the main menu screen.

4. ALTERNATOR TEST

This test is to check the MAX and MIN chargeng
voltages output of the alternator at 3000 RPM without
load and 2000 RPM with all loads ON. With this test
you can determine the alternator's condition when in
reference with the vehicle's Service Manual.
No load testing at 3000 RPM:
4.1 With engine OFF, place the vehicle
4.2 Attach the Analyser clips onto the
BATTERY
ELECTRICAL
SYSTEM ANALYSER
4.3 It will run through a self-test and
4.4 After you have made your choice,
EXIT
transmission in NEUTRAL for Manual
and PARK for Automatic and apply
the parking brake.
battery terminal posts and it will
power up and momentarily display
LCD screen as shown below:
BESA 11
when completed it displays the Main
Menu as shown below:
Select Test  
New: Clear Memory
Continue Test . . .
Last Test Result
selecting "New: Clear Memory" or
"Continue...Test" will proceed to the
main MENU, select "Starter Test" by
scrolling down:
Battery Test
Grounding Test
Starter Test
Alternator Test