AudioCodes Mediant 1000B 구성 참고 사항 - 페이지 15
{카테고리_이름} AudioCodes Mediant 1000B에 대한 구성 참고 사항을 온라인으로 검색하거나 PDF를 다운로드하세요. AudioCodes Mediant 1000B 20 페이지. Gateway & e-sbc
AudioCodes Mediant 1000B에 대해서도 마찬가지입니다: 빠른 매뉴얼 (2 페이지), 빠른 설정 매뉴얼 (8 페이지)
Configuration Note
4
Restoring Defaults using Hardware Reset
Button
You can use the device's hardware reset pinhole button to restore all the device's
configuration settings to factory defaults (including the IP address and Web interface's login
user name and password).
Note:
4.1
MP-11x Series
The procedures below describe how to reset the MP-1xx series to default settings using
the hardware reset button.
To restore MP-11x to factory default:
1.
Disconnect the Ethernet cable from the device.
2.
With a paper clip or any other similar pointed object, press and hold down the Reset
pinhole button (located on the rear panel) for about six seconds, and then release it;
the Fail LED turns red and the device restores to factory default settings.
Figure 4-1: Reset Pinhole Button Location on MP-11x Rear Panel
3.
When the Fail LED turns off, reconnect the Ethernet cable to the device.
To restore MP-124 to factory default:
1.
Disconnect the Ethernet cable from the device.
2.
With a paper clip or any other similar pointed object, press and hold down the reset
pinhole button (located on the front panel) for at least 12 seconds (but no more than
25 seconds), and then release the button.
Figure 4-2: Reset Pinhole Button Location on MP-124 Front Panel
Version 6.4
Restoring defaults using the hardware reset button is currently not applicable
to Mediant 2000 and Mediant 3000.
4. Restoring Defaults using Hardware Reset Button
15
May 2012