Daniamant Dan WL3-2 설치 및 유지 관리 지침 - 페이지 3
{카테고리_이름} Daniamant Dan WL3-2에 대한 설치 및 유지 관리 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Daniamant Dan WL3-2 4 페이지. Lifejacket light
Maintenance
Routine service
Dan WL3-2 is maintenance free, but the following checks must be made annually:
1. Inspect the light for signs of damage or corrosion.
2. Press the on/off button for and the light will commence flashing then
press the button once more and the light should deactivate.
3. To test the Sensor Switch – a paper clip may be applied to the 2 water
contacts. It is recommended that the light is activated for 1 minute.
Replacement
The Dan WL3-2 lifejacket lights have a storage life of 5 years and must be
replaced by the date shown on the label.
Health and safety information
Dan WL3-2 lights contain Lithium cells. These must be handled correctly:
•
Do not dismantle the light assembly
•
Do not make any external electrical connection
•
Do not recharge
•
Do not incinerate
Store between -30°C and +65°C
The Batteries are hermetically sealed pressurised primary Lithium/Manganese
cells, and as supplied are electrically protected by a solid-state device and are
environmentally protected by a moulded plastic housing. In this condition the units
pose no definable hazard to health.
Information on the composition and behaviour of these products is contained in
the Product Safety Data Sheet, available from our website
(www.daniamant.com) or on request.
3