Maintenance
Routine service
Dan W3-2 is maintenance free, but the following checks must be made annually:
1. Inspect the light for signs of damage or corrosion.
2. Press the on/off button and the light will commence flashing, then press
the button once more and the light should deactivate.
3. To test the Sensor, Switch and the cable – a paper clip may be applied to
the 2 water contacts. It is recommended that the light is activated for 1
minute.
Replacement
The Dan W3-2 lifejacket lights have a storage life of 5 years and must be
replaced by the date shown on the label.
Health and safety information
Dan W3-2 lights contain Lithium cells. These must be handled correctly:
•
Do not dismantle the light assembly
•
Do not make any external electrical connection
•
Do not recharge
•
Do not incinerate
Store between -30°C and +65°C
The Batteries are hermetically sealed pressurised primary Lithium/Manganese
cells, and as supplied are electrically protected by a solid state device and are
environmentally protected by a moulded plastic housing. In this condition the units
pose no definable hazard to health.
Information on the composition and behaviour of these products is contained in
the Product Safety Data Sheet, available from our website
(www.daniamant.com) or on request.
3