Danish Interpretation Systems AO 6004 사용자 설명서 - 페이지 10
{카테고리_이름} Danish Interpretation Systems AO 6004에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Danish Interpretation Systems AO 6004 13 페이지. Digital conference system audio output unit
DIS
5 System Setup
5.1
General guidelines
Connect the AO 6004 to the DCS-LAN using shielded
CAT5e cables (F/UTP or U/FTP)
Please observe the following guide lines:
Maximum cable length in one chain is 200 m
without
repeater.
•
5.2
Typical schematics
Connect the AO 6004 to the DCS 6000 network using
Cat 5 cables. The Analog Audio output connectors are
connected to either tape recorders for recording the
Figure 0-A
Typical schematic
10
This
includes
USER MANUAL AO 6004 REV B.DOCX
interconnection cables between the units.
The max. usable cable length depends on the
units connected and length of feeding cables
etc.
Maximum cable length in one chain when
using repeaters is 650 m..
•
interpreted channels or to a DT 6008 Infrared
Transmitter for transmitting the interpreted channels
wireless.
User Manual