Danish Interpretation Systems DCS 6000 사용자 설명서 - 페이지 14

{카테고리_이름} Danish Interpretation Systems DCS 6000에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Danish Interpretation Systems DCS 6000 14 페이지. Digital conference system
Danish Interpretation Systems DCS 6000에 대해서도 마찬가지입니다: 사용자 설명서 (19 페이지), 사용자 설명서 (10 페이지), 사용자 설명서 (14 페이지), 사용자 설명서 (13 페이지), 사용자 설명서 (18 페이지), 사용자 설명서 (14 페이지)

Danish Interpretation Systems

Appendix

Technical appendix

Cabling

CAT5
The DCS 6000 system uses CAT5, CAT5e or
CAT6 FTP or STP cables with screened RJ45
connectors.
EIA 568-B wiring shall be used.
It is important to use only FTP or STP
(screened) cables and screened RJ45 connectors
and not UTP cable, which is unscreened.
How to wire a CAT5 (EIA 568-B) Cable:
Pin Function
Connector
1
In-going +
ORG/WHT
2
In-going -
ORG
3
+48V
GRN/WHT
4
0V
BLU
5
0V
BLU/WHT
6
+48V
GRN
7
Outgoing -
BRN/WHT
8
Outgoing +
BRN
Note.
If other colour codes are used then the four
pairs are connected as follows:

Technical specifications

General
Power consumption ...............................................max. 150VA
Mains voltage: ........................................100 - 240V, 50...60Hz
Supply voltage for units............................................ 48V/100W
Temperature to guarantee specified performance
..............................5 Deg C. to 40 Deg C. (35 to 80% humidity)
Storage temperature
.......................... -20 Deg C. to 60 Deg C. (10 to 80% humidity)
14
#1
Connector #2
ORG/WHT
ORG
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT
BRN
Manual 01 18 04450
Pair 1:
Pin 1 & 2
Pair 2:
Pin 3 & 6
Pair 3:
Pin 4 & 5
Pair 4:
Pin 7 & 8
The phase of the pairs must be correct and the
wiring spec. as stated in CAT5 (EIA 568-B) have to
be followed.
Note: CAT6 cables can normally only be
terminated in sockets (female) and not in cable
plugs.
CAT6 can thus only be used for longer cable draws
terminating in wall outlets or patch panels.

Accessories (not supplied)

Cat 5e Connection Cables (AWG24)
EC 6000-..5 Connection Cable 0,5 m......................10 03 12500
EC 6000-01 Connection Cable 1 m.........................10 03 13101
EC 6000-02 Connection Cable 2 m.........................10 03 13201
EC 6000-05 Connection Cable 5 m.........................10 03 13501
EC 6000-10 Connection Cable 10 m.......................10 03 14102
EC 6000-20 Connection Cable 20 m.......................10 03 14202
EC 6000-50 Connection Cable 50 m.......................10 03 14502
Weight..................................................................................1 kg
Dimensions (W x H x D) ................... 100 (125) x 50 x 205 mm
Dimensions in bracket are including the fixing bracket
Accessories supplied .................................................Main cable
Connectors
DCS-LAN loop through........................................2 pieces RJ45
Specifications are subject to change without notice.
User Manual