FINE TUNING YOUR STOVE
Once the damper rod is set and your pellets are burning steadily (ie. no
popcorning), you are ready to fine tune your stove. Fine tuning is required
due to the differences in installation configuration, geography, insulation
of the home, and quality of pellets.
Do NOT use a metal object to adjust your trim
pods. Try using a plastic non-metallc object
(eg. insulated shaft screwdriver, pen cap, etc.)
First, switch to feed rate #1 by pressing the START /
FEED RATE button until the #1 LED lights up.
Turn the #1 trim pod COUNTER CLOCKWISE until
A
the dial stops, then turn back to 9-3 o'clock
position as illustrated.
Turn the #4 trim pod CLOCKWISE until the dial
B
stops, then turn back to 9-3 o'clock position as
illustrated.
By adjusting these trim pods as described above,
you are ensuring that your stove is now at its
optimal settings. You may need to adjust the
feed rates after a few days of burning.
FUEL RATES
At this point, your stove should still be running on
the #1 setting (low). Let this burn for approximately
10 minutes before making any further adjustments.
Fuel feed rate at the lowest (#1) and highest (#4) settings can be changed by adjusting
the #1 or #4 trim pods located on the control panel.
To INCREASE fuel feed rate, turn the trimmer COUNTER CLOCKWISE.
To DECREASE fuel feed rate, turn the trimmer CLOCKWISE.
IMPORTANT: The #1 and #4 trim pod dials ONLY adjust fuel feed rates 1 and 4.
WARNING: Adjusting FEED RATE #1 too low (clockwise) may cause your stove to shut down.
PELLET STOVE
ADJUSTMENTS
TRIM PODS
WITH FACTORY
DEFAULT SETTINGS
FUEL
FEED RATE
SETTING #1
(LOW)
CLOCKWISE
DECREASES
feed rate
FUEL
FEED RATE
SETTING #4
(HIGH)
COUNTER-
CLOCKWISE
INCREASES
feed rate
5