FUNCTIONNAL MODES :
eSMART MODE (or AUTO MODE) – This mode is automatically selected when an
•
AUDIOROOT eSMART Li-xxWh or LiFe-xxxWh battery is connected to one of the K-ART's
battery input. The K-ART's micro controller communicates with the battery and retrieves all
informations regarding it's state of charge and displays them on the OLED like this :
Standard MODE – This mode is selected by default when no eSMART Li-xxWh was
•
detected on the input connector. In standard mode the fuel gauge uses it's own collected
data (current, voltage, etc...) and the learned total battery capacity to display the battery's
state of charge and to predict the autonomy of the system.The total battery capacity is
measured by the fuel gauge when running the
runned by the user manually.The figure below illustrates the OLED screen display
arrangement in standard mode.
Total battery capacity :
measured during the calibrating process. This value is related to the battery index number. Up
to 8 different capacity values can be saved and selected for use.
Capacimeter :
system since the battery has been connected. The closest this value gets from the total
battery capacity the more the battery gets empty. The capacimeter's value is reset as soon as
the battery is disconnected from the fuel gauge. This value is not reset when the K-ART is
switched off (only when the battery is removed).
Battery index :
changed using the 2 push buttons located on the front panel of the unit.
http://www.audioroot.fr [email protected]
This value indicates the total capacity of the battery that was
The capacimeter shows in mAh the total current that has been drawn by the
This number indicates which battery is actually selected. It's value can be
Ce document est la propriété d'AUDIOROOT, et ne peut-être reproduit ou communiqué sans autorisation
calibration
process. This process must be