Motors
The motors are maintenance free.
It is required to check the motors once a year or in case of abnormal sound.
Heater
The regeneration heater is maintenance free, however twice a year it should be checked for
mechanical damages.
Rotor belt
It is required to carry out regular inspections of the belt tension.
Seals
It is required to carry out regular inspection of the seals for damage and dust contamination.
Transportation
Please observe the following rules of the dehumidifier transportation and storage:
Upon delivery it is required to check the dehumidifier for transportation damages.
The dehumidifier should be protected from rain and snow.
The dehumidifier should always be in upright condition.
It is not allowed to put heavy objects on the dehumidifier.
Parts list
Rotor drive motor
Condenser
Belt pulley
Rotor drive belt
Belt tensioner
Dehumidified air fan
Regeneration air fan
Heater
Rotor