2. Mark the position of the knockout on the wall where you want to fit the sensor. Drill a hole at
the mark, insert a suitable wall plug, and insert a screw (M3). The screw head must not be
more than 2.5mm from the wall surface.
3. Fix the rear housing cover on the wall. Place the sensor in the dish in such a way that a screw
closes the tamper contact. If this is not the case, unscrew the screw so that it is a little further
out of the wall.
Idle time
To increase the battery life, the sensor has an idle time function. You can reduce the idle time from
3 minutes (factory setting) to 1 minute by removing the jumper from the PCB.
To simplify the sensor test, the idle time in the first 30 minutes after battery insertion is only 10
seconds.
PIR test
1. Switch the alarm system to Walk Test mode (see the system instructions).
2. Leave the zone monitored by the sensor and wait until the idle time expires after each test
(see "Idle time").
3. Conduct different walk tests to test the monitored zone.
4. If the sensor ir unintentionally triggered, check the installation location again (see "Selecting
the installation location").