Microphone & Speaker Installation
1. Position the screen mounted microphone stem's on the customer side of
the counter top.
2. Mark the 2 fixing points and 1 cable route ready for drilling (see the
diagram below).
3. Drill pilot holes for the fixings and a cable hole if neccesary.
4. Feed wiring through the cable hole back to the amplifier and fix the
microphone in place using the supplied screws.
5. Fix the microphone head to the screen using the double-sided pad
supplied.
6. Place the staff pod on the staff side of the counter top, ensuring it
does not cause an obstruction and is as close to staff as possible. The
recommended minimum distance between this pod and the screen
mounted microphone is 300mm.
Staff Counter Side
Screen Mounted
Microphone
Speaker Pod
Staff Pod
Customer / Visitor
Counter Side
7