{카테고리_이름} Duratool D03122에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Duratool D03122 16 페이지. With t-rms/usb

Power Requirement
Dimensions
Weight

ACCURACY SPECIFICATION

The accuracy applies within one year after the calibration.
Reference condition: the environment temperature 18°C to 28°C, the relative humidity
is no more than 80%, accuracy: ±(% reading + word).

DC VOLTAGE

Range Resolution
60mV
0.01mV
600mV 0.1mV
6V
1mV
60V
10mV
600V
100mV
1000V
1V
Note: Measure in mV (60/600mV) voltage, input impedance is as high as 10 Ω, and a
weak signal of measurement does not weaken, so the measurement precision is high.
But in the circumstance that the probe is open circuit, it will display numbers, which is
normal, as long as in short circuit the probe will return to zero or if the probe is inserted
to the measured point, the reading will stabilize.

AC VOLTAGE

Range Resolution
60mV
0.01mV
600mV 0.1mV
6V
1mV
60V
10mV
600V
100mV
750V
1V
Note: Measure in mV (60/600mV) voltage, input impedance is as high as 10 Ω, and a
weak signal of measurement does not weaken, so the measurement precision is high.
But in the circumstance that the probe is open circuit, it will display numbers, which is
normal, as long as in short circuit the probe will return to zero or if the probe is inserted
to the measured point, the reading will stabilize.

DC CURRENT

Range
Resolution
600µA
0.1µA
6000µA
1µA
4 x 1.5V AA batteries
204x94x57mm (LxWxH)
About 410g (inluding batteries)
Accuracy
±(0.7% reading + 2)
Accuracy
±(0.8% reading + 3)
±(1.0% reading + 3)
Accuracy
±(1.2% reading + 3)
Input impedance: 10MΩ(60/600mV
range is 10 Ω)
11
Overload protection: 1000V DC or 750V
AC (RMS)
Maximum input voltage: 1000V DC
Input impedance: 10MΩ(60/600mV
range is 10 Ω)
11
Overload protection: 1000V DC or 750V
AC (RMS)
Maximum input voltage: 750V AC
(RMS)
Frequency range: 10Hz ~ 1kHz;
response: true RMS
Overload protection: µA/mA range:
600mA/1000V fuse (fast speed fuse)
10A range: 10A/1000V fuse (fast speed
13
11
11