Steps to configure a SAFE RAID set using USB connection (Windows XP)
1.
Open the 57xx SteelVine Manager.
2.
Insert the 2 CF cards to the CF slots on the AD2SAHDCF.
3.
Connect the USB cable to the AD2SAHDCF. The 57xx SteelVine Manager
detects the 2 CF cards in the AD2SAHDCF.
4.
Open Disk Management to check that both CF cards are detected.
*You will see an unallocated or partition depending if the CF card had been used.
Delete the partition to make it into one BIG virtual disk.
CF cards
CF cards
Screenshot of Disk Management and 57xx SteelVine Manager showing CF card
status
5.
Unplug the USB cable.
6.
Place the switch to SAFE mode.
7.
Plug back the USB cable to confirm the SAFE RAID setting.
Initial unallocated
CF card capacity
Initial BIG RAID
Setting
CF cards
New unallocated CF
card capacity for
SAFE RAID setting
New SAFE
RAID Setting