4-noks ELIOS4YOU Pro 빠른 매뉴얼 - 페이지 2

{카테고리_이름} 4-noks ELIOS4YOU Pro에 대한 빠른 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. 4-noks ELIOS4YOU Pro 2 페이지.
4-noks ELIOS4YOU Pro에 대해서도 마찬가지입니다: 빠른 매뉴얼 (2 페이지), 설치 및 사용 설명서 (17 페이지)

4-noks ELIOS4YOU Pro 빠른 매뉴얼
INSTALLATION
ATTENTION
1. Secure the device on a DIN rail, following the connections showed in the previous scheme (Fig.1
and Fig. 2).
ATTENTION:
Before installing Elios4you, remove
2. Once the device is installed and powered on, download the free Elios4you APP on your own
the label with device credentials and attach below
smart device (smartphone or tablet) from Playstore (Android) or App Store (iOS)
(or keep in a safe place) for future reference and/or
3. Open the App and start the Wizard Configuration, following the steps visible on your smartphone/
monitoring via the 4-Cloud Dashboard (web-portal)
www.4-cloud.org
tablet (read the Elios4you APP Quick Guide for further information)
4. Set correct parameters for your PV system and your energy provider using the App menu:
ID CODE: 00000
- Press
Register on:
www.4-cloud.org
- Select
and associate your device
- Select "Energy Management" and set values
with USER: XXXXXXXX
- Press OK when finished to save new values.
ATTENTION: If you are configuring the Elios4you
5. Ensure the data values are correct:
APP via the Router/AP, data will be visible via
- Press
the 4-Cloud Dashboard after approximately 1
hour from configuration.
- Check that energy "Generation" value
- Check that the energy "Consumption"
have in the property.
ATTENTION
ATTENTION: Configuring Elios4you in "Indirect Mode" grants access through the broadband Router/
AP, allowing all data to be sent to the 4-Cloud, visible remotely through the Elios4you APP (when
4-Cloud is activated) and also via the 4-Cloud Dashboard (web-portal). Go to http://www.4-cloud.
WARNING: if the generation energy LED
org and follow the instructions to register your device. Using the credentials on the label provided
does not blink when the PV installation is
(see left).
producing energy, it is necessary to invert the
Generation CT orientation by swapping the
Elios4you Front Panel Icons
connection of the wires of Elios4You (terminals
7 and 9).
Blink frequency
WARNING: if the LEDS
detect the
proportional to the
wrong energy flow ("sold" energy when it should
amount of generated
report a situation of "purchased" energy or vice
energy of the pv plant
versa), it is necessary to invert the mains CT
Blink frequency
(yellow label) by swapping the connection of the
proportional to the
wires of Elios4You (terminals 10 and 12).
amount of energy
WARNING: Ensure that the positioning of the
exchanged with the grid
Generation & Mains CTs are correct to the
If ON: energy currently
wiring of the property. Otherwise the resulting
being purchased from
measurements may not be reliable. Ensure the
the grid
Mains CT clamp is positioned after the Mains
Meter, but before the Consumer Unit. Taking into
If ON: energy currently
account any Henley Blocks / Split Junctions.
being sold to the grid
WARNING: Alterations to the length of CT
cables may cause increases in marginal errors
during measurements. We do not recommend
TROUBLESHOOT
such alterations of the device.
Problem
a. Change the Generation CT clamp (white label) orientation, by inverting the green dot (or the arrow direction inside the clamp)
1. I can't see my PV system en-
to the opposite direction.
ergy generation in the App's
b. Check that the Generation CT clamp (white label) is only clamped around the PV Live cable (not including the Neutral cable).
Home Page
c. Check that the CT clamp core is not broken or cracked inside (you may hear a buzzing noise).
d. Check that the Generation CT clamp (white label) is properly closed - be sure not to apply excessive force.
2. The energy generation visible
on the App is definitely less
a. Ensure that the Elios4you transmitter is powered from the same Live phase as the Mains CT clamp (yellow label).
than the value read from the
b. Check that the Generation CT clamp (white label) is properly closed - be sure not to apply excessive force.
inverter
a. Ensure that the Mains CT clamp (yellow label) is clamped over the Mains Live phase cable after the Mains Meter and before
3. The Consumption line has
the Consumer Unit and/or any Henley Block. Failing to do so will not give an accurate measure of total consumption.
the same shape as the Gen-
b. Ensure that the Neutral cable is not included within the Generation / Mains CT clamps.
eration line in the graph
c. Check that the CT clamp cores are not broken or cracked inside (you may hear a buzzing noise).
4. It seems that the Consump-
a. Ensure that the Mains CT clamp (yellow label) is clamped over the Mains Live phase cable after the Mains Meter and before
tion values are only being
the Consumer Unit and/or any Henley Block. Failing to do so will not give an accurate measure of total consumption.
shown in the "Grid" icon
5. I can never see "Purchased
a. Ensure that the Mains CT clamp (yellow label) is clamped over the Mains Live phase cable after the Mains Meter and before
Energy" in my system
the Consumer Unit and/or any Henley Block. Failing to do so will not give an accurate measure of total consumption.
6. During the night the con-
sumption is zero, while dur-
a. Change the Mains CT clamp (yellow label) orientation, by inverting the green dot (or the arrow direction inside the clamp)
ing the day consumption is
to the opposite direction.
always more than the ex-
pected value
a. Change the Mains CT clamp (yellow label) orientation, by inverting the green dot (or the arrow direction inside the clamp)
7. The App shows a consump-
to the opposite direction.
tion value much higher than I
b. Ensure that the Mains CT clamp (yellow label) is clamped over the Mains Live phase cable after the Mains Meter and before
would expect.
the Consumer Unit and/or any Henley Block. Failing to do so will not give an accurate measure of total consumption.
"Menu" button
"Parameter Settings"
"Home" button to to go the "Energy Performance" page
has a similar value to that from the inverter
value relative to the real-time consumption you
(red)
Power supply
(red)
Wi-Fi on
General alarm or
failed attempt to
(red)
get connected to
the smart device
Not used
(green)
Solutions
ATTENTION
DO NOT CONNECT THE SMART PLUG/
SWITCH TO:
- medical equipment: the involountary deactiva-
tion can cause life-threatening situations
- devices that can cause damage, injury or fire in
case of accidental activation (eg. irons)
- appliances that can be damaged by turning on
/ off frequently
- appliances that cannot be interrupted
- appliances that require a continuous current
supply.
ATTENTION: Always seek advice from the
manufacturer or user manual of the appliance
if it is suitable to control via radio plug or timer.
ATTENTION: Be sure to configure the Smart
Plug/Switch correctly, as per the instructions
from specific appliance manufacturers.
SMART SWITCH
SMART PLUG
(green)
(green)
LED
LED
Button
(red)
76
(green)
General Characteristics
n°8 led of functionality diagnostic; Parameter configuration with Tablet
Wi-Fi 802.11b; Access point (AP) Station (STA),B; Output Power 15 +- 1 dBm
Radio Characteristics
Red Cap (only Elios4you Smart); ZIGBEE Home Automation Profile (HA1.2)
2405 MHz ÷ 2480 MHz; IEEE 802.15.4 compatible; Nominal transmission Power +10dBm; Internal PCB Antenna
Power Supply
230Vac +- 20% 2 W
Internal Memory
Historical data up to two months with sampling every 15 minutes
External alarm: free contact connected to the inverter or auxiliary contact breakers; Lack of production in absence of
Alarms
data after 4 hours in the central time zone (from 10.00 to 14.00)
Connections
Screw terminals for 230 V ac; Screw terminals for CT; Screw terminals for signal input alarm
Antenna
Wi-Fi external antenna SMA RP connector.
Environment Parameters
Operting temperature 0 + 50°C; International Protection IP45
Compliant with directives 2004/108 CE (Directive EMC) 2006/95 CE (Low Voltage Directive)/ 99/5 CEE (Radio
CE Declarations of
Equipment Directive). Standards and/or technical specifications applied: ETSI EN 300 328v1.8.1:2012-06; ETSI EN
Conformity
301 489- 17v2.2.1:2012; ETSI EN 301 489-1v1.9.2:2011; EN 61326-1:2013; EN 60950-1:2006 + A11 (2009)
Dimensions (mm)
MANAGING APPLIANCES VIA
ELIOS4YOUSMART OR RED-CAP ACCESSORY
1. Open the Elios4You APP
2. Press Menu Button
--> Red Cap --> Activate Red Cap --> Confirm
SMART PLUG / SWITCH PAIRING
ATTENTION: When pairing devices for the first time, keep devices within close range to the Elios4you
transmitter. The devices can then be moved around to required position after pairing is complete.
The Smart Plug/Switch does not need to be close to the Wi-Fi router, as the Smart Plug/Switch
communicates using ZigBee RF (directly to the Elios4you transmitter) and not through Wi-Fi.
1. Verify that your smart device (smartphone/tablet) is within radio range of the Wi-Fi and/or
Elios4you.
2. Install the Plug/Switch to be paired to Elios4you.
3. Make sure that the Plug/Switch is not paired with a network already (Red LED flashing), otherwise
perform the disassociation before continuing (see manual for Smart Plug/Switch).
4. Select Menu icon in the Elios4you App
App --> Red Cap --> Add Smart Plug.
5. Carefully follow the Wizard in the Elios4you App.
6. Once complete, go back to the Home Screen of the App
taking you to the Consumption Details page where you will see icons for the management of
individual appliances .
7. To modify the settings of individual Plug/Switch, select the corresponding icon
NOTE: repeat the above procedure for the installation of additional Smart Plug/Switch.
ATTENTION: Within 1 minute of the pairing procedure, you will be able to see the Smart Plug/Switch
state in the Elios4you App.
DIFFERENT STATES OF THE SMART PLUG/SWITCH IN THE APP:
Button
GREY
YELLOW
Shows the OFF state (off)
Shows the ON state (on)
for both the manual mode
for both the manual mode
and/or automatic mode.
and/or automatic mode.
TECHNICAL SPECS
select the Consumption icon:
RED
Shows the OFFLINE state,
meaning the plug/switch is
off from the mains, or is out
of radio range.