Addonics Technologies RR2035ASDES 사용자 설명서 - 페이지 6

{카테고리_이름} Addonics Technologies RR2035ASDES에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Addonics Technologies RR2035ASDES 13 페이지. Raid rack

Default factory DIP Switch setting:
SW1 – RAID Setting DIP Switch
BZS – Error buzzer function
EZ –
Automatic rebuilding to spare drive (one of the drives on the raid is set as a
spare). If EZ is ENABLED anda drive failure occurs, the spare will automatically
act as a drive replacement and rebuilding will automatically start.
M2 –
RAID mode 2
M1 –
RAID mode 1
M0 –
RAID mode 0
SW1
1.
Error buzzer function is ENABLED (BZS) when dip switch is in OFF position
2.
Auto-rebuilding to spare drive is DISABLED (EZ)
3.
Individual drive mode is ENABLED (M0~M2)
Note: When the default factory RAID setting is used, independent drive configuration
and optical drive are supported only when connecting to controllers with Silicon Image
Sil3124, Sil3132 chip set or controllers that are Port Multiplier (PM) compatible.
Simultaneous DVD writing was tested using the Nero Burning Rom.
LED Pin Header
P4 P3 P2 P1 P0 P5

Error LED

J1 – Drive Activity LED
P5 –
Activity LED for eSATA host port lights up when it is connected to a SATA
controller card.
P0, P1, P2, P3 & P4 - Activity LEDs for port 0, 1, 2, 3, 4 & 5 light up when a drive is
connected and blinks when there's drive activity.
J3 – Error LED
P5 –
error LED for eSATA host port
P0, P1, P2, P3 & P4 - error LED for port 0, 1, 2, 3, 4 & 5
www.addonics.com
1
2
3
4
BZS EZ M2 M1 M0
J3
P4 P3 P2 P1 P0 P5
Technical Support (M-F 8:30am - 6:00pm PST)
5
J1

Activity LED

Phone: 408-453-6212
Email: www.addonics.com/support/query/