Now remove the steel floor plate cover.
•
Manually lift both carriages on each column about waist high. Let carriages down allowing them to set on the lift
safety lock stops. Make sure they are at the same height and on the safety lock stops.
•
Check to insure the cylinders are properly seated into the cylinder hole in the base plate. If they are, the round part
of the cylinder will be sitting down on the steel flat.
•
Take the equalizer cables. Using vise grips and a socket, tighten the cable nut half way down the threads.
•
Standing in front of the power unit main-side carriage notice the 4 holes in the top of the carriage.
•
Take the threaded end(end without nut) and run it up inside the carriage through the front hole on the right side of
the carriage. See figure 4 for cable routing. Do not tighten cables at this time. Just start them on the treads.
CONNECTING POWER UNIT & HYDRAULIC HOSES
•
Using four hex bolts mount the power unit to the main side column.
•
Install 4 inches fitting to cylinder in main side column. Small thread with sealing washer for cylinder. Large thread
for short hydraulic hose. Connect short hydraulic hose to the fitting.
•
Connect short hydraulic hose to the power unit. DO NOT over tighten, as you will crack the fitting.
•
Connect long hydraulic hose between the cylinders and let it lay inside the floor pan. DO NOT over tighten. See
figure 5 for hose layout and routing to the power unit.