Symphony64
(Compatible with ProTools Native- not to be confused with ProTools
Native-HD)
✴ Software Release Beta 3.1 or later must be downloaded from Apogeedigital.com and
installed. Following installation restart your computer.
✴ Power off Symphony I/Os
✴ Connect Loop Sync BNC cables to proper connectors in back of unit (Loop Sync Out
on Unit A to Loop Sync In on Unit B and vice versa). Make sure they don't
accidentally connect to the WC connectors!
✴ Connect 1st Symphony I/O to Symphony 64 card 1, port 1.
✴ Connect 2nd Symphony I/O to Symphony 64 card 1, port 2.
✴ Power up units. Set both Symphony I/Os in "Symphony" Audio Interface Mode (hold
in the right encoders to check and change if you need to)
✴ Launch Maestro 2 (Maestro 2 is Intel Mac only). Go to the "System Setup" tab and
check the checkbox "use Loop Sync" (in some versions of the software, the box is
ALWAYS checked and it's grayed out- this is normal). Also verify that unit A is the
"loop sync master" in the drop-down menu next to the checkbox.
✴ Open "Audio MIDI Setup" (found in Applications > Utilities > Audio MIDI Setup),
select "Symphony 64" for input and output. Set the "Source" to "PCI Card 1, Port 1-2
(Ch 1-64)".
✴ Wait for both units to lock. Unit A should be clocked to Internal displaying "INT" and
Unit B should display "LOOP".