5. Push the other end of the air feed tube onto the cup lid connector.
the pressure all you need to do is twist the two halves of the air relief valve and pull them apart. You will hear the air escape
from the cup. Reattach before spraying again. Do not mix the air relief valve with solvent as it is not made for direct contact
with solvent.

6 Operating your PBC7600-GTO Spray Gun

The PBC7600-GTO spray gun has a unique and simple fan pattern control.
Locate the Fan Adjustment Ring in the front of the spray gun. Turn the spray gun
on its side and notice the fan size indicator stamped into the spray head casting,
just to the right of the fan adjustment ring. You will notice that there is a "-" sign
at the top and a "+" sign at the bottom with two arrows indicating the direction of
rotation. Rotating the ring UPWARD will begin to reduce the size of the fan
pattern until the pattern is round. Rotating the ring DOWNWARD will provide a
full, open, wide pattern. (Relative to the distance the spray gun is held from the
work surface).
To adjust the direction of the fan pattern, loosen the air cap ring, (Fig. 1) rotate the air cap ears (Fig. 2) to either a vertical or
horizontal position as noted in the diagram. This will provide your vertical or horizontal fan pattern.
Fig. 1 Use this position when spraying across from side to side.
Fig. 2 Use this position when spraying from top to bottom.
Fig. 3 Use this position for spotting small objects, corners and sharp angles and touch up.
Install the appropriate fluid nozzle, needle assembly and color-coded air cap (A, B, C or D) for the viscosity of the fluid being
sprayed. See Chart B for recommendations. Prepare your coating as you would normally, (Thinning if necessary). Filter and
pour into spray gun cup.
NOTE:
Make sure you attach the air feed tube so that the black end of the air valve is pointing
towards the cup lid as shown in the illustration.
NOTE:
Above the non-return valve, you will see an air relief valve. The purpose of this valve it to
release pressure from the cup prior to opening the cup lid to prevent paint splatter. To release
Spray Patterns
5