1
Parameter
The parameter overview is help a sought-after parameter for finding fast and changing. The construction of the list
has already been explained in the list using structure.
There are parameters, which can be found in the technicians' and developers' level both different consequences,
however, have. All settings in the developers' level aren't accessible for using staff and service technicians but are
adjusted by the software developers to the certain hardware once.
1.1
Parameter of class 867
class:
t 08 04
set of parameters:
for sub-class:
1.1.1
Operator-level
L
C
P
Min
Bobbin thread counter and bobbin thread monitor
o
06
00
0
o
06
01
0,1
o
06
02
0,1
o
06
03
0,1
o
06
04
1
o
06
05
0
o
06
06
0
o
06
07
0
o
06
08
0
Needle cooling
o
13
00
0
867
867-190x22-M
867-190122-M
Max
Preset Unity
4
0
-
999,9
300,0
x o0602
999,9
200,0
x o0604
999,9
100,0
x o0604
255
10
x stitches
9999
0
stitches
1
1
-
1
1
-
1
0
-
1
0
-
Description
Activate the bobbin thread counter
0 = off;
1 = Bobbin thread counter A;
2 = Bobbin thread counter B;
3 = Bobbin thread counter C;
4 = Bobbin thread monitor
Reset value
of the bobbin thread counter A
Reset value
of the bobbin thread counter B
Reset value
of the bobbin thread counter C
Factor of the bobbin thread counter A, B, and C
Number of stitches for bobbin thread monitor
Stopping motor if the counter has reached the value 0.
0 = off;
1 = on
Sewing foot down after thread trimming.
0 = off;
1 = on
Display of the bobbin thread counter value
0 = off;
1 = on
Needle cooling
0 = off;
1 = on
II-4