3
Order
1. Assemble the throat plate slide interrogator ( p. 5).
2. Connect the throat plate slide interrogator.
3. Test functionality ( p. 15).
Information
If not yet present on the machine, the adapter (part no. 0867 592224)
must be assembled first.
The plug connection X6 (IN) of the circuit board must ALWAYS be
connected to the machine distributor. The corresponding cable is
included.
Depending on the type of machine distributor, the plug connection and
setting must be established:
Machine distributor
9850 688001 (DA178)
9850 867000 (DA174)
9850 867020 (DA289)
9850 838000 (DA199)
10
Connecting the throat plate slide interrogator
WARNING
Risk of injury from sharp and moving parts!
Crushing, cutting and punctures are possible.
Do not connect the throat plate slide interrogator
unless the machine is switched off and de-energized.
Disconnect the machine from the power supply
before connecting the interrogator.
NOTICE
Property damage may occur!
The cables may be crushed, kinked and cut.
Make sure not to guide the cables over sharp edges and moving
parts and do not kink or crush the cables.
Connecting the throat plate slide interrogator
Plug
Comment
X15
J1 must be open (OFF)
X26
J2 must be open (OFF)
X29
S2 must be open (OFF)
X23
S2 in position 1-OFF; 2-ON; 3-OFF