If there is a fault with the charger, please check carefully all external wires whether they are connected
correctly. If it is not wire faulty, you can check indicators' fault codes and their corresponding solutions as
follows:
INDICATOR STATE "."
SHOW PAUSE
Red-Green-Red-Green-Red-Green
Red-Green-Red- - -
Red-Green-Red-Green-
Green-Red- - -
Red-Green- - -
Red-Green-Red-Green-Red
Green-Red-Green- - -
12

TROUBLESHOOTING:

INDICATION
Without load
Overvoltage or over current
The ambient temperature
is too high or too low
Charger Overheating
Output Under Voltage
Input AC abnormality
Any one of the above-mentioned
faults repeats five times, then
it appears.
FAULT
Check if these happen: the connection
between battery and charger is loose,
the battery is reversed, or the battery
voltage is too low.
If the error opens again after the restart,
return it to factory repair.
Please check if the ambient temperature
is too high and if ventilation is good and
the position of the battery temperature
sensor.
Please check whether the ambient tempe-
rature is too high and if ventilation is good.
Please return it to the factory.
Please check the input voltage and the
plug's poor contact.
Re-up electricity, match the indicator
state to the above-mentioned faults
then get the corresponding solution.
Lithium Battery Charger User Manual