Lithium Battery Charger User Manual
PROTECTION
FUNCTION:
a. Protection for Reverse Connection: There is no DC output for the charger when the batteries are
-
connected reversely and will not damage the charger.
b. No-load Protection: There is no DC output when the batteries are not connected.
c. Temperature Protection: When the ambient temperature exceeds 40°C, the charger automatically
reduces the current or turns off for protection. When the temperature is restored, the charger
automatically resumes charging.
d. Short Circuit Protection: The charger will turn off when a short circuit is an output. The charger will
restart charging only after troubleshooting.
e. Automatic Shutdown after Full Charging: The charger automatically turns off after the battery is fully
charged according to the charger's judgment. Only when AC power is disconnected or the battery is
recommended, the charger can recharge.
f. Lock on Indicator (Optional): According to the requirements of the vehicle design. The charger can
make the car not in motion condition, the charging process through a normally open or normally closed
unit to control the vehicle electronic control parts.
g. Outlet Indicator (Optional): When recharging, the charger will control the vehicle according to the
need, and the charge lamp will show the current charging status of the battery. The specific way of
learning about display mode, please verify with the vehicle manufacturer.