Datacom Systems FTP-8000 Series 빠른 시작 매뉴얼 - 페이지 3
{카테고리_이름} Datacom Systems FTP-8000 Series에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Datacom Systems FTP-8000 Series 3 페이지. Tap
Tap Series FTP-8000/9000
FASTstart Guide
When installing a Fiber Tap, it is important to make sure that the Tx and Rx fibers
are connected to the respective ports on the Fiber Tap. When wired correctly, the traffic incoming on
an Rx port will be split before being sent to two separate Tx ports (One copy to the other Network
device, the other copy to Monitor).
If the fibers are connected backwards, light will not be received on the monitoring
port. This is because the internal coupler that splits the light is unidirectional.
Fiber Tap will still send light between the network ports and connectivity will be seen on both network
endpoints. Be sure to check the for light on the monitor ports as well as the network ports when
installing the Fiber Tap.
Customer Service
is available from our website: www.datacomsystems.com or by calling +1 315 463 9541
© 2015 Datacom Systems, Inc
541-0149-R
Reverse wiring can be difficult to catch initially, since an incorrectly cabled
For More information
Page 3
DATACOM
S Y S T E M S I N C