Cavity Sliders Solic CS005 운영 매뉴얼 - 페이지 2

{카테고리_이름} Cavity Sliders Solic CS005에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cavity Sliders Solic CS005 16 페이지. Automatic sliding door operator, motor - m005 (hypoid gear type)

1. FEATURES
1. Digital counter for door cycles
The digital counter on the microcomputer control box counts the number of cycles
the door completes over its life. A cycle is one movement open and then closed.
This number is memorised even if the power is turned OFF. This counter is useful
for maintenance requirements. Maximum Value for counter: 9,999,999.
2. Electronic Motor lock
The control circuit for the optional electronic lock (Motor Lock - LK01) has been
built into the controller. The lock is easily attached to the CS Motor - M005 before
or after door installation. The door lock engages when the door is closed and
securely locks the door. This operation is controlled by the CS microcomputer
when the door is activated to Open.
3. Simple movement setting adjustment
Accessory screwdriver supplied with controller allows easy adjustment of the
following basic movement settings:
• Door hold open timer
• Door closing speed
4. Test button switch
The test button switch (White) for door opening and closing is provided on the
microcomputer control box. The hold timer, door opening and closing speed are
easily checked with this switch.
5. Various functions
There are a variety of extra functions that are available on the microcomputer that
are not supplied for use with the doors.
• Opening adjust width
The use of these extra functions requires the supply of an additional wiring loom
(L003) from CS FOR DOORS. An electrician will be required to wire the activation
gear to work with these functions.
6. Push to Open
When the door is pushed open manually a short distance, the controller will take
over and automatically open and close the door through a standard open cycle.
This can only be done if the motor lock is disengaged.
7. Obstacle detection
When the door closes and runs into an object it will stop and reopen. When it
closes the second time it will slow and check if the obstacle is still present before
continuing to close.
Slow close distance
Direction of door opening
• Breakaway function
• 24V AC
2