Cavius FLOOD 매뉴얼
{카테고리_이름} Cavius FLOOD에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cavius FLOOD 2 페이지.
Commercial reference: 5101-003
Developed by CAVIUS
PLEASE
READ THE USER GUIDE
CAREFULLY BEFORE USE AND
RETAIN FOR FUTURE USE!
The Flood Alarm is designed to detect a leak of
water from washing machines, water pipes or
under-sink cabinets. It can also be used to detect
flooded basements.
TECHNICAL INFORMATION:
The maximum number of alarms that can be inter-
linked within a house group is 32.
Please note: These must be alarms from the CAVIUS
The distance between interlinked alarms depends on
the house layout and they should always be tested
after installation. It is not advised to get more than
10m distance between two alarms.
Diameter: 60mm. Height: 37mm.
The alarm is powered by a replaceable 3v CR123A
lithium battery. Please note that correct operation of
the flood alarm device is ensured by use of one of
the following batteries: DURACELL, PANASONIC or
HUIDERUI.
Interlinked by RF: 868 MHz.
Complies to standards: RoHS, REACH, R&TTE
(EN300-220-1 and 2), EMC directive 2004/108/EC.
SENSOR
PINS
1.
HOW TO SET UP AND CONNECT ALARMS:
1. Open the flood alarm top
cover by twisting counter
clockwise.
2. Remove the Test button / Lid
to accessto the battery and
the RF learn slide switch.
3. Start by pulling out the battery isolation strip as
shown.
DO NOT
REMOVE THE
PRODUCT LABEL
ISOLATION
STRIP
UK
Please note: The product label must not be
removed as it contains important information
regarding the product.
All alarms that need to be connected in the
house should be put into 'Learn Mode' by sliding
the switch on the top of the alarm to the 'Learn
mode' position.
1
NORMAL MODE
The red LED will light up to indicate that 'Learn
Mode' has been selected.
Do not take out the battery during 'Learn Mode' as
this will interrupt the learn process.
Press and hold the test button at one alarm only,
until it beeps and the LED flashes. This alarm will
become the master and will start sending out a
specific house code to the other alarms.
1
As the other alarms receive the specific house
code, they will also flash the LED light.
SOUND
When all alarms flash the red LED, they are
connected and can be switched out of 'Learn
Mode' and installed.
4. Switch out of 'Learn Mode' by sliding the switch
on the top of the alarm to the 'Normal mode' position.
NORMAL MODE
5. Remount the Test
button / Lid.
6. Close the flood alarm
top cover by twisting
clockwise.
2
LEARN MODE
2.
THE BEST AREAS TO INSTALL THE
FLOOD ALARM:
• Install a flood alarm where it is hard to discover
possible leaks.
• Install next to washing machine, dishwasher,
uder-sink cabinet or in the cellar.
• Install in basements.
Place the alarm where it is reachable in order
to test the battery.
Minimum flood alarms
Minimum heat alarms
2
3.
AREAS WHERE NOT TO INSTALL FLOOD
ALARMS:
• On the ceiling.
• On the wall (unless using accessory wall
mounting base, see section 5).
• In rooms where temperature goes outside
0°C to 40°C.
Place the alarm where it is reachable in order
to test the battery.
4.
PLACEMENT:
The flood alarm is designed to be placed on the
floor near to possible leaks.
NOTE: If you place the flood alarm in places
where a potential water leak / flood can rise higher
than 2cm, there is a risk of your flood alarm beeing
damaged. In these places we recommend wall
mounting base with probe.
Minimum smoke alarms