Datalogic CBX500 설치 매뉴얼 - 페이지 14
{카테고리_이름} Datalogic CBX500에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Datalogic CBX500 17 페이지. Scanning connection box
Datalogic CBX500에 대해서도 마찬가지입니다: 설치 매뉴얼 (16 페이지), 설치 매뉴얼 (17 페이지)
CBX500 INSTALLATION MANUAL
TECHNICAL FEATURES
ELECTRICAL FEATURES
Supply Voltage
Consumption
Limited Current Consumption
CBX + reading device consumption
(see related manual)
Inputs 1 and 2
Inputs 3 and 4
Outputs 1 and 2
Output 3
USER INTERFACE
LED Indicators:
Power On/Polarity Error (blue/red), Trigger (yellow), IN2 (green)
PHYSICAL FEATURES
Mechanical Dimensions
Weight
ENVIRONMENTAL FEATURES
Operating Temperature
Storage Temperature
Humidity max.
Vibration Resistance
EN 60068-2-6
2 hours on each axis
Shock Resistance
EN 60068-2-27
Protection Class
EN 60529
The features given are typical at a 25 C ambient temperature (if not otherwise indicated).
* for further details about minimum/maximum supply voltage refer to the manual of the
connected reading device, since the minimum supply voltage required may be >10.
** when compression connectors and reading device are correctly connected.
If Host Interface (Fieldbus) Modules are used, only correctly installed IP65 models
guarantee IP protection. Protection is not guaranteed when Standard Fieldbus Modules
are mounted.
14
Non opto-isolated polarity insensitive
30 Vdc max; 40 mA max continuous
OUT1 (yellow), OUT2 (green)
10 to 30 Vdc*
0.5 – 0.3 A
2.5 A Max
30 Vdc max; 12 mA max
Non opto-isolated Pass through
Opto-isolated polarity sensitive
130 mA max pulsed
Non opto-isolated Pass through
193 x 180 x 71 mm
(7.6 x 7.1 x 2.8 in.)
about 780 g. (27.5 oz.)
0° to 50 C (+32° to 122 °F)
-20° to 70 C (-4° to 158 °F)
90% non condensing
14 mm @ 2 to 10 Hz
1.5 mm @ 13 to 55 Hz
2 g @ 70 to 200 Hz
30 g; 11 ms;
3 shocks on each axis
IP65 **