DX8200A QUICK GUIDE
Network Termination:
When building a Lonworks system the network must be properly terminated by positioning the BTK-8102
Lonworks terminator in the DX8200A master reader and the BTK-8100 Lonworks bus return in the last DX8200A
slave reader.
The BTK-8100 bus return provides a connector to be inserted in the Lonworks 17-pin female connector of the last
slave reader in the network; while the BTK-8102 Lonworks terminator provides a different connector to be
inserted in the Lonworks 17-pin male connector of the master reader:
DX8200A Master
DX8200A Last Slave
BTK-8100
BTK-8102
CAB-810X
Network
CAB-810X
BTK-8102 and BTK-8100
Two cables are also provided as accessories to terminate and power the network: CAB-8605 and CAB-8305.
CAB-8605 is a power and Lonworks termination cable to be used for connecting the DX8200A master to an
external power unit within the network; while CAB-8305 is a power and bus return cable to be used for connecting
the last DX8200A slave to an external power unit. This two cables must be used only for VDC models.
DX8200A Master
DX8200A Last Slave
Network
Power Unit
CAB-8305
CAB-8605
CAB-8605 and CAB-8305
7