Power-off-to-Unlock type:
12V 300mA
-
+
Jumper position in 1-2
2) Door Lock Controlled with External
Power
1. The external power supply must be used
according to the lock.
2. The jumper must be taken off before
connecting.
3. Setup the Unlock Mode Parameter for
different lock types
•
Power-on-to-unlock type:Unlock
Mode=0(by default)
•
Power-off-to-unlock type:Unlock
Mode=1
4. If different unlocking time is needed,
change the unlock time on door station,de-
tail information refer to DT system techni-
cal guide .
Power-on-to-Unlock type:
+
Take off the Jumper
-12-
+12V
LK -
LK+
N.O.
EB-
EB+
Exit button
1 2 3
JP_LK
Cut off the line
-
+
+12V
LK - (GND)
LK+(COM)
N.O.
-
EB-
EB+
Exit button
1 2 3
JP_LK
Power-off-to-Unlock type:
-
+
+
-
Exit button
Take off the Jumper
10. Specification
Power supply:
Power Consumption Of Outdoor Station:
Power Consumption Of Indoor Unit:
Unlock Power output:
Unlock timing:
Working temperature:
Wiring:
Dimension:
5.2(H)×8.9(W)×0.71(D) inch(Indoor Unit)
12.32(H)×5.04(W)×2.48(D) inch(flush)
12.32(H)×5.04(W)×2.76(D) inch(surface)
Cut off the line
+12V
LK - (GND)
LK+(COM)
N.O.
EB-
EB+
1 2 3
JP_LK
26Vdc
1W in standby;
5W in working.
0.29W in standby;
7W in working.
12Vdc,250mA
1~99s
- 20ºC ~ +55ºC
2 wire, non-polarity