Datalogic 939501109 빠른 참조 매뉴얼

{카테고리_이름} Datalogic 939501109에 대한 빠른 참조 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Datalogic 939501109 2 페이지. Ccd scanner

Datalogic 939501109 빠른 참조 매뉴얼
8
[0.30]
8
[0.31]
MØ3
[Ø0.12] N°4
25
[0.98]
50
[1.97]
Mechanical Dimensions
TC1200-1X00
CCD Scanner
Quick Reference Guide
The TC1200-1X00 is a linear CCD Scanner for OEM applications. It is available in two
different versions:
Model
Description
TC1200-1000
CCD Reader, RS232
TC1200-1100
CCD Reader, USB
Technical Specifications
Power supply
5 Vdc  5%
Consumption
350 mA; 1.75 W
Interfaces
RS232, USB
Max Scans/sec
320
Max resolution
0.076 mm (3mils)
EAN/UPC, Code 39, Code 32, Code 128, GS1-128, ISBT 128,
Readable codes:
Interleaved and Standard 2 of 5, Codabar, ABC Codabar,
GS1 Databar (Omnidirectional, Limited, Expanded), Code 93,
Code 11, MSI
Default Configuration
Enabled Interface
RS232, 9600, N, 8, 1, ACK/NAK disabled, inter-character delay
disabled, Enable Character = E, Disable Character = D
Reading
Illumination Mode = Triggered, Operating Mode = On-Line, Phase
Parameters
Off Event = Trigger Stop, LED Indication = On Decode, Label
Programming Mode enabled
Data Format
Data Transmission = On Decode, Prefix (Header) = <NUL>, Suffix
(Terminator) = <CR>, Code ID disabled, No Read Character =
<CAN>, Code Verifier disabled, Case Conversion disabled
Code Selection
 Code EAN-8, EAN-13, UPC-A, UPC-E: without Add-On, Check
Digit transmitted, no conversions
 Code 39: length: variable 2 - 50
Enabled codes
 Code 128: Check Digit not transmitted, length: variable 1 - 80
 GS1-128: transmit labels in GS1-128 data format
Other Parameters
Digital Outputs disabled, Power Save disabled, no Advanced
Formatting
Order Number
939501108
939501109