1.2. IN-OUT wiring with DBC One-user distributor
5
ON
1 2
3 4 5 6
Code=32, DIP-6=on
4
ON
1 2
3 4 5 6
Code=31, DIP-6=off
4
ON
1 2
3 4 5 6
Code=8, DIP-6=off
4
ON
1 2
3 4 5 6
Code=1, DIP-6=off
3
DPS
A
1
ID=00
1 2
3 4 5 6
ON
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
C
PS5
2
85~260AC
[1]: Door Station, when there is only one Door Station,
the DIP bit-1 and bit-2 should be set to 00.
[2]: Power Supply(PS5), MUST be installed side by side
with the DPS unit.
7
[3]: Power Separator, MUST be installed side by side
with the PS5 unit.
[4]: Monitor, each one with a unique User Code (Max.32
Monitors), the bit-6 of the DIP should be set to
the Monitor is not at the end of the bus line.
[5]: Monitor, the bit-6 of the DIP should be set to
if the Monitor is connected at the end of the bus line.
6
[6]: DBC(DT Branch Controller) unit, each apartment
B
use one DBC unit to connect to the bus, except the last
apartmet at the end of the bus line.
[7]: DBC(DT Branch Controller) unit, at the end of
the bus line, can connect two apartments, the last
apartment and the 2nd last apartment.
6
When Monitor quantity < 20
Cable Usage
Twisted cable 2x0.75 mm
Twisted cable 2x1 mm
When Monitor quantity > 20
Cable Usage
Twisted cable 2x1 mm
Twisted cable 2x1.5 mm
- 3 -
0
(off) if
1
A
B
60
60
30
2
80
80
40
2
A
B
C
70
30
20
2
70
50
30
2
(on)
C