Datalogic 952001321 사용 설명서
{카테고리_이름} Datalogic 952001321에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Datalogic 952001321 7 페이지. Contrast sensor
This product is covered by one or m ore of the following patents.
European Patent 851,211 B1; 1,111,690 B1; 1,148,346 B1; 1,209,487 B1.
Italian Patent IT 1,321,772.
S5N-PA/MA...W
Contrast sensor
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED
The yellow LED on indicates that the N.O. (normally open) output status
is closed.
READY LED
The green LED indicates a normal operating function.
If the green LED flashes, the acquisition has failed.
Please refer to the "SETTING" paragraph for setup procedure
indications.
SET PUSHBUTTON
A long pressure on the pushbutton activates the self-setting procedure.
INSTALLATION
S5N-PA...W : The sensor can be fixed by means of the M18x1 threaded
body through a 18 mm hole, using the specific washer and the
enclosed 24 mm nuts (maximum torque of tightening 1.5 Nm).
Alternatively, the sensor can be mounted through the two housing's holes
using two screws (M3x22 or longer) and nuts.
Amongst the various possible solutions, we suggest to choose the
combination that offers the best visibility of the signalling Leeds and the
easiest access to the SET pushbutton.
22 mm nuts, h=8 mm, (2 Nm maximum tightening torque) are available to
guarantee an improved torque.
S5N-MA...W : The sensor can be fixed by means of the M18x1 threaded
body through a 18 mm hole, using the two CH.24 nuts enclosed (22
Nm maximum tightening torque).
For both plastic version and metallic version are available various
orientable fixing brackets to ease the sensor positioning (please refer to
the accessories listed in the general catalogue).
The operating distance is measured from the front surface of the sensor
lens.
CONNECTIONS
The connections are compliant to the EN 60947-5-2 standard.
BROWN
1
+
10 ... 30 Vdc
WHITE
2
N.C. OUTPUT
4
BLACK
N.O. OUTPUT
3
BLUE
0 V
S5N-PA VERSION
S50-PA VERSIONS
81.5
14.5
2
1.5
3.5
4
4
CABLE VERSION
25
43
2.5
10
SET PUSHBUTTON
N°.2 Ø3.8
READY L ED
STABILITY LED
OUTPUT LED
34
15
OUTPUT LED
TECHNICAL DATA
S5N-PA PLASTIC VERSIONS
Power supply:
Ripple:
Current consumption
(output current excluded):
Outputs:
Output current:
Output saturation voltage:
Response time:
Switching frequency:
Jitter
Indicators:
Setting:
Operating mode:
Data retention:
Operating temperature:
Storage temperature:
Insulating strength:
Insulating resistanc e:
Operating distance (typical values):
Minimum spot dimension:
Emission type:
Ambient light rejection:
0.5 mm amplitude, 10 ... 55 Hz frequency, for every axis (EN60068-2-6)
Vibrations:
Shock resistance:
Housing:
Lenses:
Mechanical protection:
Connections:
Weight:
75 g. max. cable vers.
25 g. max. connector vers.
AtEx 2014/34/EU
Emission:
M12 CONNECTOR
+
N.C. OUTPUT
2
1
(WHITE)
3
4
-
0 V
(BLUE)
DIMENSIONS
S5N-MA VERSION
S50-MA VERSIONS
67
14.5
4
4
10
43
2.5
10
SET PUSHBUTTON
READY L ED
STABILITY LED
READY L ED
STABILITY LED
49
OUTPUT LED
mm
S5N-MA METALLIC VERSIONS
10 ... 30 Vdc (limit values)
2 Vpp max.
25 mA max.
N.O. and N.C.; PNP or NPN; 30 Vcc max. (short-circuit protection)
100 mA max.
2 V max.
100 s
5 kHz
50 s
OUT PUT LED (YELLOW) / LED READY (GREEN)
SET pushbutton
LIGHT mode on N.O. output / DARK mode on N.C. output
non volatile EEPROM memory
-10 ... 55 °C
-20 ... 70 °C
500 Vac 1 min., between electronics and housing
>20 M 500 Vdc, between electronics and housing
10 mm 2 mm
4.5 mm
white light LED (400-700 nm)
according to EN 60947-5-2
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
PBT
Nickel plated brass
PMMA
IP67 Metal versions type 1 enclosure
2 m cable 4 mm / M12 - 4 pole connector
110 g. max. cable vers.
60 g. max. connector vers.
II 3D EX tc IIIC IP67 T 85°C
Exempt Risk Group (RG0) according to IEC 62471
EASY TOUCH
The sensor uses the patent-covered EASY TOUCH technology that
allows a rapid and safe self-setting of the product.
Two different setting possibilities are available:
- EASY TOUCH
; a long pressure of the SET pushbutton allows self-
10 ... 30 Vdc
setting.
- FINE DETECTION; to be used only in particularly critical conditions,
(BROWN)
this setting procedure is used only when the EASY TOUCH is not
N.O. OUTPUT
sufficient.
(BLACK)
Setting of S5N-PA/MA...W
To achieve a correct sensor functioning, the coloured mark or object to
be detected has to be placed at the right reading distance.
- EASY TOUCH
(standard detection in the DARK m ode)
The EASY TOUCH technology allows the functioning in the DARK
mode (mark presents a lower light intensity respect to the
background).
The mark to detect has to be placed correctly at the right reading
distance within the sensor spot.
Press the SET pushbutton until the READY LED turns OFF.
Release the SET pushbutton and wait for the READY LED to turn ON.
The sensor is now ready to detect the pre-set coloured mark or object
CABLE VERSION
(output LED turns ON when the N.O. output is closed).
10
- Fine detection (DARK or LIGHT m ode)
This mode offers an improved detection precision.
The sensor can function either in the DARK operating or in the LIGHT
operating mode (light-coloured mark on dark background).
The operating mode is selected automatically by the sensor.
READY L ED
STABILITY LED
OUTPUT LED
The mark to detect has to be placed correctly at the right reading
distance within the sensor spot.
Press the SET button until the READY LED turns OFF.
Hold the SET button until the READY LED turns ON (3s).
The sensor is acquiring the mark.
When the READY LED flashes slowly, position the background to
coincide with the sensor spot and press the SET button again.
If the READY LED lights up permanently, the acquisition has been
successful; if the LED flashes quickly, the acquisition has failed due to
insufficient contrast. Pressing the SET button returns the sensor to
the previous setting. Repeat the procedure from the beginning.
The output LED is ON and the N.O. output is closed, when the sensor
is positioned on the pre-set coloured mark.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
T el: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions,
Support.
For information about the disposal of Waste Electrical
and Electronic Equipment (WEEE), please refer to the
website at www.datalogic.com.
© 2007 - 2020 Datalogic S.p.A. and/or its affiliates ALL RIGHT S
RESERVED. Without limiting the rights under copyright, no part of this
documentation may be reproduced, stored in or introduced into a retrieval
system, or transmitted in any form or by any means, or for any purpose,
without the express written permission of Datalogic S.p.A. and/or its
affiliates. Datalogic and the Datalogic logo are registered trademarks of
Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All
other trademarks and brands are property of their respective o wners.
Datalogic reserves the right to make modifications and improvements
without prior notification.
826000442 Rev.C
SETTING