Calibration SET

Sets a threshold exactly at the presented condition
Threshold can be adjusted using "+" and "-" Navigation key (Manual Adjust)
A single sensing condition is presented, and the sensor positions a threshold exactly at the presented condition. When a condition lighter
than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO switch setting (see LO/DO Switch in
Interface).
Calibration SET and Manual Adjust
Moves switching threshold value up or down to make adjustments
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
- GREEN display shows the switching threshold value
- 2 seconds after adjustment, the GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Remember: Auto Thresholding is automatically disabled in Calibration SET
Follow these steps to perform a Calibration SET:
Note: TEACH Selection must be programmed to CAL SEt (see
1. Enter Adjust Mode
Method
SET Button 17
Remote Input 18
SET Button: 0.04 seconds ” "Click" ” 0.8 seconds
17
Remote Input: 0.04 seconds ” T ” 0.8 seconds
18
Sensor positions
threshold exactly at
the presented condition
Output OFF
Darkest
(no signal)
Figure 8. Calibration SET (Light Operate shown)
Action
Set Mode switch to ADJ
No action required; sensor is ready for
Calibration SET method
Threshold position
adjusted by
Manual Adjust
Output ON
Condition
Most Light
Presented
(saturated
signal)
Program
Mode)
Display: Red - Signal Level;
13
Top Panel
Result
Green - Threshold