Dark SET and Manual Adjust
Moves switching threshold value up or down to make adjustments
•
Slide Mode switch to ADJ to enter Adjust mode
•
Press "+" to increase; press "-" to decrease
GREEN display shows the switching threshold value
2 seconds after adjustment, the GREEN display will flash 3 times to confirm
•
Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Dark SET:
Note: TEACH Selection must be programmed to dr SEt (see
1. Enter Adjust Mode.
Method
SET Button 14
Remote Input 15
2. SET Sensing Condition.
Method
SET Button
Remote Input
3. Return to RUN Mode.
Method
SET Button
Remote Input
SET Button: 0.04 seconds "Click" 0.8 seconds
14
Remote Input: 0.04 seconds T 0.8 seconds
15
See
Troubleshooting
on page 16 for more explanation of the % Offset displayed after the Dark SET method.
16
Action
Set Mode switch to ADJ
No action required; sensor is ready for Dark
SET method
Action
•
Present sensing condition
•
Click the SET Navigation key
•
Present sensing condition
•
Single-pulse the remote input
Action
Move Mode switch to RUN
No action required; sensor returns to RUN
mode automatically
Program
Mode)
Display: Red - Signal Level; Green -
Threshold
Threshold Condition Accepted
Displays read "dr SEt" then alternate
"PASS" with % Offset 16 ; Sensor
returns to Adjust mode
T
Threshold Condition Not Accepted
Displays read "dr SEt" then alternate
"FAIL" with minimum % Offset 16 for
sensing condition; Sensor returns to
Adjust mode
Display: Red - Signal Level;
12
Result
Result
Result
Green - Threshold