Datalogic S70-5-E1-PZ 매뉴얼 - 페이지 8

{카테고리_이름} Datalogic S70-5-E1-PZ에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Datalogic S70-5-E1-PZ 18 페이지. Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies

Datalogic S70-5-E1-PZ 매뉴얼
4. Exit Dynamic TEACH.
Method
SET Button
Remote Input
5. Return to RUN Mode.
Method
SET Button
Remote Input

Window SET

Sets window thresholds that extend a programmable % offset above and below the presented condition
All other conditions (lighter or darker) cause the output to change state
Sensing window center can be adjusted using "+\" and "-" Navigation key (Manual Adjust)
Recommended for applications where a product may not always appear in the same place, or when other signals may
appear
See Program Mode in the user's manual for programming the Offset Percent setting (to increase/decrease the window size)
A single sensing condition is presented, and the sensor positions window thresholds a programmable % offset above and below the presented
condition. In LO mode, Window SET designates a sensing window with the Output ON condition inside the window, and the Output OFF
conditions outside the window (see Fig.4).
Output ON and OFF conditions can be reversed using the LO/DO switch (see LO/DO Switch in
See
Troubleshooting
on page 16 for more explanation of the % Minimum difference displayed after the Dynamic TEACH method.
7
Action
Click the SET Navigation key
Single-pulse remote input
Action
Move Mode switch to RUN
No action required; sensor returns to
RUN mode automatically
Output OFF
Darkest
(no signal)
Figure 4. Window SET (Light Operate shown)
T
Sensing window
center adjusted by
Manual Adjust
Sensor positions
window thresholds
a programmable %
offset from the
presented condition
Output ON
Output OFF
Condition
Most Light
Presented
(saturated
signal)
8
Result
TEACH Accepted
Displays alternate "PASS" with %
Minimum Difference 7 , Sensor returns
to Adjust mode
TEACH Not Accepted
Displays alternate "FAIL" with %
Minimum Difference 7 , Sensor returns
to Adjust mode
Result
Display: Red - Signal Level;
Green - Threshold
Top Panel
Interface).