CONNECTIONS
Connections should always be made with power OFF!
CAUTION
Datalogic Skorpio™ Serial/Modem Cradle can be connected to a Host by means of an RS232 interface or can
provide a modem connection by means of the integrated modem through the RJ11 phone connector.
RS232 Connection
The Datalogic Skorpio™ Serial/Modem Cradle can be connected to the Host by means of cable 94A054000 for 9-
pin connections. The RJ45 connector of the cable must be connected to the RS232 port of the cradle.
Then, it is necessary to insert the power supply plug into the power jack on the base of the cradle and attach
the power supply to a power outlet.
Once the Host has been turned on, insert the mobile computer into the cradle.
A
Figure 4 - RS232 Connection
Key:
A)
Host computer
B)
94A054000 9-pin serial cable
C)
Datalogic Skorpio™ Serial/Modem Cradle
D)
94ACC4595 FPS18 power supply without power cord
94ACC1150 Power cord EU 3-pin
Pinout
The cable 94A054000 allowing the RS232 connection has the following pinout:
Cradle side
RJ45
1
2
3
4
5
Figure 5 - Cable 94A054000 Pinout
B
C
D
Host/PC side
9-pin D-sub
(female)
TX
2
RTS
8
GND
5
CTS
7
RX
3
4
1
Modem Connection
The Datalogic Skorpio™ Serial/Modem Cradle has an integrated modem and provides a modem connector
which can be used with an RJ11 connector. It can be connected to a telephone line to transfer data to a Host.
B
A
Pin
1
2
3
4
It is not possible to use the serial connection and the modem connection at the same time.
By default, the Datalogic Skorpio™ Serial/Modem Cradle allows serial communication
through the rear RS232 connector. It is mandatory to use an appropriate custom
software application in order to use the cradle integrated modem port.
CAUTION
Power Supply
Each connection requires a power supply to be connected to the cradle. We recommend the DL FPS18
power supply.
Figure 3 - Power Supply Polarity
To reduce electrical noise, install the included ferrite onto the cradle side of the
power cord. Wind the power cord three times around the ferrite, as shown in the
figures below.
NOTE
Key:
A)
Phone line to remote Host
B)
Datalogic Skorpio™ Serial/Modem Cradle
C)
94ACC4595 FPS18 power supply without
power cord
C
Name
not connected
TIP
RING
not connected
VEXT
GND