Analog low level (-10 dBV): this setting can be
used with equipment that has a lower output
level, such as consumer electronics The
maximum peak input level before clipping is
+10 dBV.
· ·
AES3 left (AES3 L): the left channel of a supplied
AES3 signal will be used.
· ·
AES3 right (AES3 R): the right channel of a
supplied AES3 signal will be used.
· ·
AES3 mono (both "AES3 L" and "AES3 R"
indication LEDs are illuminated): the AES3 signal
will be mixed to a mono signal.

Cooling fan

The 8c is equipped with a hybrid cooling system.
During normal use, natural convection cooling
will suffice to keep the amplifier and electronics
at normal operating temperature range. In case
of heavy use, a fan provides additional cooling as
necessary. The fan speed is regulated to maintain a
low noise level.
In case of extreme overheating, the 8c will shut
down to prevent damage to its electronics.

Fuse

A 10A fuse is located in the fuse drawer (15) in
between the mains input and power switch. If the
loudspeaker should not switch on upon operation
of the power switch, inspect the fuse to make sure
that it is intact. Disconnect the power cable and pry
open the fuse drawer with a small flat screwdriver
and, if necessary, replace the fuse inside. Make sure
to use the correct rating (10A).
If a fuse fails, it is most likely due to an internal
electrical fault and replacing the fuse will not solve
the problem. In case the new fuse also fails, the
product needs to be serviced.
11