DataOn Storage DNS-2640 사용자 설명서 - 페이지 4

{카테고리_이름} DataOn Storage DNS-2640에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. DataOn Storage DNS-2640 17 페이지. 2u 24-bays sas iii jbod

 
DNS-2640 Overview
Form Factor
Drive Support
Drive Form Factor
I/O Controller
Host Interface
SAS Expander
Controller Support
Server Host Support
Disk Drive
Enclosure Cooling
Power Supply
Drive Zoning
LED Indicators
Enclosure
Dimensions
Weight
Failure Notification
Operational
Environment
Safety Standers
 
2U 24-bay 2.5"
12Gb/s & 6Gb/s SAS 3.0 HDD and SSD
2.5" Disk Device
Dual Redundant 12Gb/s SAS 3.0 Controller Module
Six 12Gb/s SAS 3.0 SFF-8644 connections per I/O
PMC Sierra PM8055 SXP 48-port 12Gb/s SAS expander
12Gb/s SAS RAID & SAS HBA
Supports up to Six Server/Host with six host interface
24 x 12Gb/s or 6Gb/s dual-ported SAS SSD & HDD
Dual Cooling Fan Module built-in Power Module
725W Delta® 1+ 1 Redundant Power Supply
1 x 24, 2 x 12 and 3 x 8 Split-bus Zoning via Firmware
*Identify Enclosure
*Identify Drive
3.5" H x 17.6" W x 19.5" D
Enclosure only: 48lbs
SCSI Enclosure Services (SES-3) over in-band & LEDs
Temperature: 5o to 35o C
Temperature gradient: 20o C per hour
Relative Humidity: 10% to 80% (non-condensing) Humidity gradient: 10% per hour
Altitude: -200 to 10,000 ft.
Shock: 5G at 11ms, ? sine wave pulse
Vibration: 0.15G at 5Hz to 500Hz
Acoustics: 6.5 Bels at normal operation tested to ISO7779
CE Mark, EN55022/EN61000 Class A, FCC Class A, VCCI Class A
UL 60950 CSA 22.2-950, IEC 60950, EN60950
*Power On & Activity
*Drive Rebuild
with 24 drives: 72lbs
DNS-2640 User Manual
*Drive Fault
3